Play n Tools

Free tools & games for everyone

Free · No sign-up · No accounts

Fluid flow calculator

Pressure drop and pump power for pipes, flow through holes and nozzles, how long a tank takes to drain, and how much a ditch or gutter carries.

How to use

  1. Pressure drop in a pipe: pick the fluid and pipe, and type the flow, inside diameter and length. Add the K values of fittings (a 90° elbow is about 0.3 to 1.5, an open ball valve about 0.05, a tee through the branch about 1 to 2).
  2. Orifice and nozzle: the flow through a hole or nozzle at a given pressure difference.
  3. Draining a tank: how long a round tank takes to empty through a hole or tap.
  4. Open channel or ditch: how much water a gutter, ditch or channel carries at a given depth and fall.

Keyboard and touch

Enter in a boxWork it out
TabMove between boxes and lists
Changing a listUpdates the answer straight away

Tips

  • Pressure drop rises roughly with the square of the flow: double the flow, about four times the drop.
  • A slightly bigger pipe helps a lot: going from 20 to 25 mm cuts the drop to about a third.
  • Use the inside diameter, not the nominal size: they differ, especially for plastic pipe.
  • For the cylinders, pumps and hoses of hydraulic machines, use the Hydraulics & pneumatics calculator.
  • This is for learning and estimating. Gas piping, fire sprinklers, drinking-water mains and anything safety-related must be designed by a qualified person to the local code.

About this calculator

Pipe flow uses the Darcy-Weisbach equation, Δp = f (L ÷ D) ρv² ÷ 2, plus ΣK ρv² ÷ 2 for fittings. The friction factor is 64 ÷ Re for laminar flow (Re below 2300) and comes from the Colebrook-White equation for turbulent flow, solved by iteration; between 2300 and 4000 the flow can switch either way. Fluid densities and viscosities are typical table values.

Orifice flow: Q = Cd A √(2Δp ÷ (ρ(1 − β⁴))), where β is the hole-to-pipe diameter ratio. Tank draining follows Torricelli's law, giving time = (A_tank ÷ (Cd a)) √(2 ÷ g) (√h₀ − √h₁). Open channels use Manning's formula, V = (1 ÷ n) R^⅔ S^½ in SI units, with typical roughness values n. Everything runs in your browser.