Compare solar panels, work out daily energy and panel count, size the battery, check string lengths against inverter limits and add up inverter load.
| From the data sheet | Panel A | Panel B |
|---|---|---|
| Power at STC (W) | ||
| Length (mm) | ||
| Width (mm) | ||
| Temp. coefficient of Pmax (%/°C) | ||
| NOCT (°C) |
| Tab | Move between boxes and tabs; results update as you type |
|---|---|
| Enter or Space | Open the tab that has focus |
Efficiency = watts ÷ (area in m² × 1000 W/m²). Cell temperature = air temperature + (NOCT − 20) ÷ 800 × sunshine (the NOCT model). Output = rated watts × sunshine ÷ 1000 × (1 + temperature coefficient × (cell temperature − 25 °C)).
Energy per day = array watts × peak sun hours × system performance. Panels needed = daily use ÷ one panel’s daily energy, rounded up. Battery capacity = daily use × days ÷ (usable depth × inverter efficiency); amp-hours = watt-hours ÷ battery voltage. Charging current ≈ panel watts ÷ battery voltage.
Strings: a voltage at temperature T = voltage at 25 °C × (1 + coefficient × (T − 25)). The longest safe string is the inverter’s maximum DC voltage ÷ the cold Voc, rounded down. The tracking window needs the hot Vmp of the string above the lowest MPPT voltage and the cold Vmp below the highest. Strings in parallel per tracker = the input current limit ÷ Imp (and the short-circuit limit ÷ Isc), rounded down.
Inverter load: running watts add up. The start-up peak assumes the appliance with the largest extra start-up power starts while everything else runs; “all at once” adds every start-up figure. The suggested continuous rating adds 25 % headroom. Battery current = watts ÷ (battery voltage × inverter efficiency). These are planning figures, not an installation design.
The tests check every formula against worked examples and an independent Python version.