Solar panel & battery calculator

Compare solar panels, work out daily energy and panel count, size the battery, check string lengths against inverter limits and add up inverter load.

From the data sheetPanel APanel B
Power at STC (W)
Length (mm)
Width (mm)
Temp. coefficient of Pmax (%/°C)
NOCT (°C)

How to use

  1. Compare panels: copy the watts, size, temperature coefficient and NOCT from each panel’s data sheet. Set a hot sunny day to see what each one really gives when the cells heat up.
  2. Energy & panel count: type the panel power, how many you have and your peak sun hours. Add your daily use to see how many panels cover it.
  3. Battery size: type the energy you use from the battery each day and how many days it must last without sun.
  4. Strings & inverter limits: copy Voc, Vmp, the currents and the temperature coefficients from the panel data sheet and the voltage and current limits from the inverter or charge controller data sheet. The table shows which string lengths fit.
  5. Inverter load: list the appliances that may run at the same time, one per line, with running and start-up watts from their labels.

Keyboard

TabMove between boxes and tabs; results update as you type
Enter or SpaceOpen the tab that has focus

Tips

  • Peak sun hours are the day’s sunshine squeezed into hours of full 1000 W/m² sun. Look them up for your place and panel tilt on a national solar map such as NREL’s PVWatts in the US; winter values can be a third of summer ones.
  • System performance of 75 to 80 % covers heat, dirt, wiring and inverter losses for a typical home system.
  • A smaller (less negative) temperature coefficient means less power lost on hot days.
  • To find your daily use, add up watts × hours for each device, or read your power bill (kWh per month ÷ 30). Our Power outage planner helps with backup runtimes.
  • Use the record low air temperature for your area as the coldest cell temperature: panels can be that cold at sunrise, when open-circuit voltage is highest.
  • Hot cells in summer sun often reach 60 to 75 °C, about 25 to 35 °C above the air.
  • Wiring, fuses, breakers and connecting to the grid must follow electrical codes; have a qualified electrician design and check the installation.

About the calculations

Efficiency = watts ÷ (area in m² × 1000 W/m²). Cell temperature = air temperature + (NOCT − 20) ÷ 800 × sunshine (the NOCT model). Output = rated watts × sunshine ÷ 1000 × (1 + temperature coefficient × (cell temperature − 25 °C)).

Energy per day = array watts × peak sun hours × system performance. Panels needed = daily use ÷ one panel’s daily energy, rounded up. Battery capacity = daily use × days ÷ (usable depth × inverter efficiency); amp-hours = watt-hours ÷ battery voltage. Charging current ≈ panel watts ÷ battery voltage.

Strings: a voltage at temperature T = voltage at 25 °C × (1 + coefficient × (T − 25)). The longest safe string is the inverter’s maximum DC voltage ÷ the cold Voc, rounded down. The tracking window needs the hot Vmp of the string above the lowest MPPT voltage and the cold Vmp below the highest. Strings in parallel per tracker = the input current limit ÷ Imp (and the short-circuit limit ÷ Isc), rounded down.

Inverter load: running watts add up. The start-up peak assumes the appliance with the largest extra start-up power starts while everything else runs; “all at once” adds every start-up figure. The suggested continuous rating adds 25 % headroom. Battery current = watts ÷ (battery voltage × inverter efficiency). These are planning figures, not an installation design.

The tests check every formula against worked examples and an independent Python version.