Free tools & games for everyone
Free · No sign-up · No accounts
Work out the number and height of stair risers, tread depth, total run, angle and stairwell opening from your floor-to-floor height.
| Step | Height of the tread | Nosing from the first riser |
|---|
Geometry only. Building rules differ between countries, states and towns, and change over time: your local building department decides. This page does not size stringers, supports or guards, and a "within" result is not an approval.
| Tab | Move between the boxes |
|---|---|
| Enter | Calculate |
| Space | Open or close the step table |
The number of risers is the total rise divided by your target, rounded, and raised by one until the riser is no taller than the chosen rule allows. Treads are one fewer than risers. The stairwell opening is (headroom + floor thickness) × tread ÷ riser, measured back from the top riser along the slope of the nosings.
Common limits used for the checks: International Residential Code R311.7 (riser at most 7 3/4", tread at least 10", headroom at least 6' 8", width at least 36", one flight at most 12' 7" high, nosing when the tread is under 11"); Approved Document K for a private stair in a home in England (rise at most 220 mm, going at least 220 mm, pitch at most 42°, 2R + G from 550 to 700 mm, headroom 2.0 m). These figures were checked on 18 November 2026; your local version may differ.
Nothing is stored or sent: everything runs on your device.
A fresh daily puzzle every morning, and new tools added every month.
Browse every product