Play n Tools

Free tools & games for everyone

Free · No sign-up · No accounts

Hydroponics and greenhouse lab

Hydroponic and greenhouse maths: nutrient doses and dilution by EC, ppm scales, daily light integral, and greenhouse heat loss, heating energy and fans.

of nutrient in 1 litre:

Find the EC rise yourself: add a measured amount to a known volume of water, stir, and measure. For example, 10 ml in 10 L raising the EC by 0.25 is a rise of 0.25 per ml per litre.

How to use it

  1. Pick your crop: each tab compares your numbers with its typical range.
  2. Nutrients: give the reservoir size, the EC now and the EC you want, and how much your nutrient raises the EC (measure it once). The lab gives the amount to add, or the water to add if the EC is too high.
  3. Light: give the light level at the plants (PPFD, from a quantum meter or the light’s chart) and the hours the light is on.
  4. Greenhouse: give the size of a gable greenhouse, its cover, the temperature to keep and the coldest night, and see the heat lost, the energy, the cost and the summer fan flow.

Keyboard

TabMove between tabs, boxes and buttons
Enter in a boxWork it out

Tips

  • EC meters show the strength of the solution; ppm meters show the same reading multiplied by 500, 640 or 700, depending on the meter. Compare ppm figures only on the same scale.
  • Plants take up water faster than nutrients, so the EC rises between top-ups. Top up with plain water first, then adjust.
  • Always follow the label of your nutrient, wear gloves when handling concentrates and keep them away from children. Adjust pH with products made for it, a little at a time.
  • Bubble wrap or a second layer on the cover lowers U, and stopping draughts lowers the air changes: both cut the heating bill.

About this tool

Nutrient sums treat the EC rise as proportional to the amount added, which is close for the small changes used in practice, and mixing as a volume-weighted average. The daily light integral adds up the photons over the day: PPFD × hours × 3,600 seconds ÷ 1,000,000.

Heat loss uses typical U-values for each cover (watts per square metre per degree) and 0.33 watt-hours to warm one cubic metre of air by one degree. Crop EC, pH and light ranges are typical starting values from growing guides; varieties and growth stages differ. This is a planning aid, not professional advice.

The tests check every formula against a separately written Python version and against worked examples. For sowing dates, see the planting calendar.

See you tomorrow!

A fresh daily puzzle every morning, and new tools added every month.

Browse every product